IMPORTANT: If you are an existing Dorse customer, register to see account pricing – or contact your sales rep for help.
Close
(0) items
You have no items in your shopping cart.
Preferences
Search

Centrifugal Upblast Exhaust Fan, Product # CUBE-160-10122G3QD-DR1, 2038-3306 CFM

$2,561.00

The CUBE is an aluminum exhaust fan specifically designed for roof or sidewall mounted applications where contaminated or grease laden exhaust air can be discharged directly upward, away from the roof or wall surface. The fans feature a one piece windband continuously welded to curb cap and double studded isolators for true vibration isolation.

  • 22 x 22 inch base with prepunched mounting holes for easy attachment to roof curb
  • 18.5 x 18.5 inch recommended roof opening
  • Roof or wall mountable
SKU: CUBE-160-10122G3QD-DR1
Ships From: Greenheck

View Related Products

Available In: 5-7 Business Days
Dimensions
Base/Panel Length X Width
Square base dimension on power roof ventilators. Square fan panel dimension on sidewall propeller fans.

22 x 22 in

Curb Cap Size
Square base dimension on power roof ventilators.Tells you what size roof curb is needed.

22 in

Impeller Diameter
Dimension of the impeller (propeller or wheel) in inches.

17 in

Roof Opening Width x Roof Opening Length
Describes the size (width x lenght) of the roof opening that is required in order to properly install a given fan or ventilator.

18 1/2 x 18 1/2 in

Base Height
Height of the curb cap on power roof ventilators.

1 3/4 in

Damper Width x Damper Height
The "ACTUAL" damper width and height. Dampers are undersized to allow them to be mounted into the duct work/wall opening.

16 x 16 in

Bearing Size
Bore size on the bearings utilized on a ventilator.

3/4 in

Height
The height of a given product.

29 3/4 in

Weight
Weight

80 lbs

Overall Diameter
Describes the diameter at the widest point for a given product.

28 7/8 in

Performance
CFM Range
CFM Range

2038-3306

FRPM Range
FRPM Range

970-1150

Application
Application
Applications/uses for a particular fan or ventilator.

Exhaust General and Clean Air

Exhaust Grease-Laden Air

Exhaust General and Clean Air

Exhaust Grease-Laden Air

Mounting Location
Refers to the location where a fan or ventilator can be mounted.

Roof

Wall

Roof

Wall

Construction Features
Drive Type
Transmission type of the ventilator (belt drive or direct drive).

Belt Drive

Impeller Type
Style of impeller that is utilized on a product (i.e. Centrifugal or Axial).

Centrifugal Wheel

Impeller Material
Type of material the impeller of a fan or ventilator is constructed of.

Aluminum

Housing Material
Type of material the housing of a ventilator is constructed of.

Spun Aluminum

Includes
Describes items that a particular product includes such as mounting hardware, etc.

Unassembled drive package

Max Inlet Temp
The maximum entering air temperature that a fan or ventilator can withstand while in operation, without compromising the life of the unit.

400 °F

Certifications
Certifications

AMCA Sound & Air

UL/cUL 705 Listed - Supplement SC - "Power Ventilators for Restaurant Exh. Appliances" (Formerly UL 762)

AMCA Sound & Air

UL/cUL 705 Listed - Supplement SC - "Power Ventilators for Restaurant Exh. Appliances" (Formerly UL 762)

Drive Package Description
Describes whether the drive package on a particular ventilator is assembled, shipped loose, or must be provided by the customer.

Motor and drives shipped loose

Required Accessory
Describes what accessory(s) must be purchased in addition to make the product fully functional.

Roof curb for new roof installations

Motor Information
Service Factor
A safety factor to be used when the load temporarily exceeds the nominal horse power rating of a given motor. When used on a motor nameplate, a number which indicates how much above the nameplate rating a motor can be loaded without causing serious degrad

1.15

Phase
Indicates the space relationships of windings and changing values of the recurring cycles of AC voltages and currents. The most common power supplies are either single- or three-phase.

3

Voltage
The force that causes a current to flow in an electrical circuit. The voltage of a motor is usually determined by the supply to which it is attached. NEMA requires that motor be able to carry its rated horsepower at nameplate voltage plus or minus 1% al

208-230/460

HP
The power required to drive an air moving device. Horsepower required varies with system conditions.

1

Hertz
Measure of the frequency or cycles per second.

60

Motor Enclosure
The housing or frame of the motor.

Open Drip Proof

RPM
The number of times per minute the shaft of the motor (machine) rotates. This is a function of design and the power supply.

1800

Motor Insulation
The class of motor insulation for a given motor. The temperature capabilities of each insulation class is defined as being the maximum temperature at which the insulation can be operated to yield an average life of 2, hours (A = 15?C, B = 135?C, F =

F

Nominal Efficiency
Nominal Efficiency

83.5

NEMA Frame Size
Refers to a set of physical dimensions of motors as established by NEMA (National Electrical Manufacturers Association). These dimensions include critical mounting dimensions.

56

General
Unit of Measure
Unit of Measure

ea

Warranty Length
Warranty Length

1 Year

Model CUBE is an aluminum exhaust fan specifically designed for roof or sidewall mounted applications where contaminated or grease laden exhaust air can be discharged directly upward, away from the roof or wall surface. The fans feature a one piece windband continuously welded to curb cap and double studded isolators for true vibration isolation. Ideal for new installations or for retrofit, replacement applications. Curb adapters and reducers available to eliminate the need to field fabricate transitions when there is an existing roof curb.

  • Centrifugal wheel provides high-efficiency and minimal sound
  • One-piece aluminum windband with rolled bead provides extra rigidity
  • Cooling fins located on top of fan wheel draw outside air through a large breather tube directly into the motor compartment extending motor life
  • Windband is continually welded to the curb cap and drain trough for leakproof construction
  • Machine cast pulleys are adjustable for final system balancing
  • Permanent embossed aluminum nameplate for exact model and serial number identification
  • Motor, belt and pulleys shipped loose for field assembly