IMPORTANT: If you are an existing Dorse customer, register to see account pricing – or contact your sales rep for help.
Close
(0) items
You have no items in your shopping cart.
Preferences
Search

Centrifugal Inline Fan, Model BSQ-120, Belt Drive, 1 1/2HP, 115/208-230V, 1Ph, Motor & Drives Unassembled, 1352-2255 CFM

$2,990.00

Model BSQ centrifugal inline fan features a unique combination of installation flexibility, rugged construction, ease of service, high efficiency and low sound levels. These compact fans are the ideal selection for indoor clean air applications including intake, exhaust, return or make-up air.

  • 15.875 x 15.875 inch inlet width x height
  • 15.875 x 15.875 inch outlet width x height
  • Horizontal or vertical mounting
SKU: BSQ-120-15X-QD-DR1
Ships From: Greenheck

View Related Products

Available In: 5-7 Business Days
Dimensions
Inlet Width x Height
Describes the size (width x height) of the opening where air is drawn into a ventilator.

15 7/8 x 15 7/8 in

Outlet Width x Height
This dimension refers to the size of the discharge (where air leaves the ventilator) on a particular unit.

15 7/8 x 15 7/8 in

Impeller Diameter
Dimension of the impeller (propeller or wheel) in inches.

13 in

Damper Width x Damper Height
The "ACTUAL" damper width and height. Dampers are undersized to allow them to be mounted into the duct work/wall opening.

16 x 16 in

Bearing Size
Bore size on the bearings utilized on a ventilator.

3/4 in

Height
The height of a given product.

35 in

Depth
Maximum depth of a product.

19 in

Weight
Weight

134 lbs

Performance
CFM Range
CFM Range

1352-2255

FRPM Range
FRPM Range

1830-1990

Application
Application
Applications/uses for a particular fan or ventilator.

Exhaust General and Clean Air

Recirculate Air

Supply Air

Exhaust General and Clean Air

Recirculate Air

Supply Air

Exhaust General and Clean Air

Recirculate Air

Supply Air

Mounting Location
Refers to the location where a fan or ventilator can be mounted.

Indoor

Inline

Indoor

Inline

Mounting Position
Refers to the orientation in which a product can be mounted.

Horizontal

Vertical

Horizontal

Vertical

Construction Features
Drive Type
Transmission type of the ventilator (belt drive or direct drive).

Belt Drive

Impeller Type
Style of impeller that is utilized on a product (i.e. Centrifugal or Axial).

Centrifugal Wheel

Impeller Material
Type of material the impeller of a fan or ventilator is constructed of.

Aluminum

Housing Material
Type of material the housing of a ventilator is constructed of.

Galvanized Steel

Includes
Describes items that a particular product includes such as mounting hardware, etc.

Motor cover

Unassembled drive package

Motor cover

Unassembled drive package

Max Inlet Temp
The maximum entering air temperature that a fan or ventilator can withstand while in operation, without compromising the life of the unit.

160 °F

Certifications
Certifications

AMCA Sound & Air

UL/cUL 705

AMCA Sound & Air

UL/cUL 705

Drive Package Description
Describes whether the drive package on a particular ventilator is assembled, shipped loose, or must be provided by the customer.

Motor and drives shipped loose

Motor Information
Phase
Indicates the space relationships of windings and changing values of the recurring cycles of AC voltages and currents. The most common power supplies are either single- or three-phase.

1

Voltage
The force that causes a current to flow in an electrical circuit. The voltage of a motor is usually determined by the supply to which it is attached. NEMA requires that motor be able to carry its rated horsepower at nameplate voltage plus or minus 1% al

115/208-230

HP
The power required to drive an air moving device. Horsepower required varies with system conditions.

1 1/2

Hertz
Measure of the frequency or cycles per second.

60

Motor Enclosure
The housing or frame of the motor.

Open Drip Proof

RPM
The number of times per minute the shaft of the motor (machine) rotates. This is a function of design and the power supply.

1800

Motor Insulation
The class of motor insulation for a given motor. The temperature capabilities of each insulation class is defined as being the maximum temperature at which the insulation can be operated to yield an average life of 2, hours (A = 15?C, B = 135?C, F =

B

Thermal Protection
This is a feature which protects the motor from overheating and thus prolongs service life of the machine. In the event that the motor approaches overheating the thermal protection cuts power and only returns it after a cooling period.

AutoOverload

General
Unit of Measure
Unit of Measure

ea

Warranty Length
Warranty Length

1 Year

Model BSQ centrifugal inline fan features a unique combination of installation flexibility, rugged construction, ease of service, high efficiency and low sound levels. These compact fans are the ideal selection for indoor clean air applications including intake, exhaust, return or make-up air systems where space is a prime consideration. The square housing design eliminates the need for square-to-round transitions, reducing installation costs. With straight-thru airflow, system designers also have flexibility to mount the BSQ in any configuration - horizontal, vertical or at any angle.

  • Removable access panels allow easy access to all interior components
  • Aluminum, centrifugal wheel delivers maximum efficiency
  • Inlet and discharge duct collars allow for easy duct connection
  • Rigid, galvanized steel housing construction
  • Factory tested bearings designed specifically for air handling applications with a minimum L₁₀ life in excess of 100,000 hours
  • Motor, belt and pulleys shipped loose for field assembly
  • Permanent embossed aluminum nameplate for exact model and serial number identification